| Sign In | Join Free | My polstate.com | 
 | 
Brand Name : Lensen
Model Number : LS-RAO02
Place of Origin : China
MOQ : 2pcs
Price : Negotiation
Payment Terms : T/T, Western Union
Supply Ability : 6000pcs/month
Delivery Time : 2-7 days
Packaging Details : standard carton
Frequency : 433MHz/450MHz/470MHz
Power output : 1W
Distance : 2km
Output : 2 analog output
Application : sensors wireless transmission
Signal : 4-20mA or 0-5V
LS-RAO02 wireless analog acquisition module
 
LS-RAO02 Modbus RTU is a 1W I/O module, 2 analog outputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for sensor and PLC/HMI wireless communication
 
Parameter
 
| Frequency | 433MHz or 450MHz or 470MHz | 
| Power output | 1W | 
| Products | 2AO | 
| Input type | 4-20mA or 0-5V or 0-10V | 
| Output type | 4-20mA or 0-5V or 0-10V | 
| Resolution ratio | 24 bit | 
| Accuracy | ±0.02% | 
| Power supply | 9-36V DC usually use 24V DC | 
| Interface | RS-485 | 
| Channel No. | 16ch default, can program via DIP switch | 
| Antenna | Sucker antenna with 1.5m cable | 
| Working temperature | -35 °C ~ +75 °C industrial | 
| Working humidity | 10%-90% relative humidity, no condensation | 
| Dimension | 115×90×40(mm) | 
| Fix way | Standard 3.5 inch industrial DIN guild rail | 
 
 
 
Application:
 
Wireless pump controls
Automate your tank level without running wire between the well pump and the tank. Wireless pump controls save you time and money.
 
Wireless tank level monitoring
simple wireless monitoring of your tank level from a remote location and receive critical status updates.
 
Wireless valve activation
Open or close electronic wireless valves, solenoid valves.
 
Smart Agriculture
Pivot irrigation, soil pressure and temperature monitoring
 
Emergency notification
Receive critical status updates by email, phone, cell phone, or PDA if equipment fails
 
Conveyor Control
Control a conveyor motor remotely
 
Remote Control Relay
Use dry contact inputs to control a remote relay.
 
Problem Notification
Save time in large facilities by activating an overhead notification light when a problem occurs, letting the supervisor know exactly where to go.
 
Dust Suppression
Use wireless I/O module to operate your dust
 
Data Logging
Wirelessly acquire and log various data from a remote location using our analog I/O module
 
Stacker Control
Start and stop your stacker/reclaimir. Connect PLC in control center with stacker and reclaimer.
 
Proximity Detection
Mount a transmitter with adjustable range on heavy equipment, mount a receiver in a “blind spot,” and then set up the receiver to sound an alarm or turn on a light whenever the equipment is operating in the area.
 
Chemical Level Monitoring
Monitor water chlorination or other chemicals remotely.
 
Traffic Signals
Avoid having to lay new wire by using wireless transmitters and receivers to control traffic signs such as “Railroad Crossing Ahead” when a train is present.
 
Grain Elevators
Our wireless transmitters and receivers can be used to monitor grain elevator conditions or control different functions. To collect RS485 data. To monitor temperature and humidity in Grain.
 
Freight Loading
Digital I/O module for crane control and analog I/O module to send the load information wirelessly to another location.
 
Modbus RTU communication and corresponding value 
 
Register types:
| Register types | Read command | Write command | Power off | Function | 
| Hold register | 0x01 | Input --not support | Not keep | Can read input value | 
| 0x03 | 
 
A. Hold register
1. Analog input value: 0x0008~0x000B
2. Analog output value: 0x0048~0x004B
 
B: How to read
Hold register: can read 4 analog input or control 4 analog output at one time
 
Register control way
 
| AI/AO | IC | Read/ | Function ID | items support | ||
| No. | IC Type | PLC ID | Modbus ID | |||
| AI1 | Hold register | 40009 | 8 | Read | 03 | 2AI/4AI | 
| AI2 | Hold register | 40010 | 9 | Read | 03 | |
| AI3 | Hold register | 40011 | 10 | Read | 03 | 4AI | 
| AI4 | Hold register | 40012 | 11 | Read | 03 | |
| AO1 | Hold register | 40073 | 72 | Read/write | 03/06 | 2AO/4AO | 
| AO2 | Hold register | 40074 | 73 | Read/write | 03/06 | |
| AO3 | Hold register | 40075 | 74 | Read/write | 03/06 | 4AO | 
| AO4 | Hold register | 40076 | 75 | Read/write | 03/06 | |
 
About value calculation
Analog input
Our analog module’s max measure range value is : 0X7FFF
1. Directly measure current and voltage
Exact value=value you read/0x7FFF*max range
For example: to read the 1st passage of module’s (with max range of 0-20mA) input value
Register 0x0008(analog input of the 1st passage)
Feedback: 0x3801
Current value: (0x3801/0x7FFF)*20mA=8.7509mA
 
2. To measure sensor’s value(4-20mA, 0-6 meter level sensor)
If feedback value is less than 6554, level value is 0
If feedback value is bigger than 6554, level value=(value read-6554)/(32767-6554)*measure ranges
For example: feedback value is 0X3801, then corresponding level value is: ((0X3801-6554)/26213)*6 meter=1.7815 meter
 
Analog output
Analog module’s max measure range is: 0x7FFF
Directly control output current and voltage
Write register value=current or voltage value/measure range*0x7FFF
For example: to control the 1st passage of analog module whose max measure range is 0-20mA
Register 0x0048 (analog output of the 1st passage)
To write register value:(8.75/20mA)*0X7FFF =14336=0x3800
 
|   | 
| Wireless Analog Output Module 433MHz Wireless RTU collect 4-20mA, 0-5V, 0-10V signal Images | 
 4-20mA Wireless I O Module 433MHz Level Sensor Wireless Signal Transmission 2km
                                                                                    
                        
                        
                        
                                                            4-20mA Wireless I O Module 433MHz Level Sensor Wireless Signal Transmission 2km
                                                    
                        
                     4-20mA Wireless I O Module Analog Input / Output Module Wireless Sensor
                                                                                    
                        
                        
                        
                                                            4-20mA Wireless I O Module Analog Input / Output Module Wireless Sensor
                                                    
                        
                     Industry Wireless I O Module Ethernet DI DO Wireless AI AO Controller 1W Power
                                                                                    
                        
                        
                        
                                                            Industry Wireless I O Module Ethernet DI DO Wireless AI AO Controller 1W Power
                                                    
                        
                     4-20mA Analog Wireless I O Module 2 Channels Free Band Wireless Control 2KM+
                                                                                    
                        
                        
                        
                                                            4-20mA Analog Wireless I O Module 2 Channels Free Band Wireless Control 2KM+
                                                    
                        
                     2 Channels Wireless I O Module 0-5V Analog Input / Output 433MHz RS485 Interface
                                                                                    
                        
                        
                        
                                                            2 Channels Wireless I O Module 0-5V Analog Input / Output 433MHz RS485 Interface
                                                    
                        
                     4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless
                                                                                    
                        
                        
                        
                                                            4 Channels Analog I O Module Wireless Analog Inputs 4-20mA / 0-5V Wireless
                                                    
                        
                     2-3km Wireless I O Module 4-20mA Wireless Signal Transmission 2 Channels AI 0-5v
                                                                                    
                        
                        
                        
                                                            2-3km Wireless I O Module 4-20mA Wireless Signal Transmission 2 Channels AI 0-5v
                                                    
                        
                     433MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog
                                                                                    
                        
                        
                        
                                                            433MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog
                                                    
                        